Tủ trung tâm chữa cháy CLVR 2 zones COFEM CLVR02EXT

Tủ trung tâm chữa cháy CLVR 2 zones COFEM CLVR02EXT

- COFEM CLVR02EXT là tủ trung tâm điều khiển tự động hệ thường 2 zones với chức năng chữa cháy. Đạt tiêu chuẩn EN 54-2, EN 54-4, EN 12094-1 và CE mark.

Features 

- 2 zones control panel with extinguishing functionality for conventional detectors and call points use.

- Third additional zone configurable as an alarm and detection zone for conventional detectors and call points or as a monitoring input of an external fire protection system.

- Same technical features as conventional CLVR control panels (2 general sounder outputs, 1 alarm output, 1 fault output, 230Vdc outputs, test mode, threshold setup, metallic cabinet, etc).

- 3 modes of operating extinction:

   + Standard mode: Output R1 of pre-warning is activated with Zone 1 or Zone 2 in alarm status.

   + Consecutive mode: Output R1 is activated intermittently (1 second with Zone 1 or Zone 2 in alarm status, 0,5 seconds with Zones 1 and 2 in alarm status, and continuing once the output R2 delay is finished).

   + Simultaneous mode: Output R1 is activated with Zones 1 and 2 in alarm status.

- Stop and activation extinguishing button directly in the control panel.

- Possibility to install manual stop and activation buttons near the flood zone.

- 1 extinction output (”R2”) supervised, temporized supervised, temporized between 0 and 60 seconds, protected by a resettable fuse.

- Delay for R2 extinguishing output reset after extinguishing activation temporized between 0 and 30 minutes.

- MODBUS protocol over RS485 on demand.

- Possibility of ON-LINE software in a PC using the MODBUS functionality.

- CONTACTID on demand.

- Certified according EN 54-2, EN 54-4 and EN 12094-1 with CE mark.

Đặc tính kỹ thuật 

Model CLVR02EXT
Supply voltage 110/230VAC 50/60Hz
Output voltage 21 V Nominal
Max. consumption 70 VA at 230 V/AC
Batteries 2x12V7 Ah SLA
Extinction fuse R1/R2 0,5A/0,75A autoreset
Batteries charger 500 mA 27 V/DC 20ºC
Devices par zone 32
Control panel power supply 2,2 A
Max. current per zone 2 mA (in standby)
End of line capacitor 4 K7
Sounder output voltage 30 V/DC
Environmentals conditions -10ºC +50ºC
Size 363 x 331x96 mm
Weight (without batteries) 4,3 Kg
Standard EN 54-2, EN 54-4&EN 12094-1
30v max. current output 1,5 A
Extinction module fuse 1,85 A autoreset
S1 output sounder fuse 1,85 A autoreset
S2 output sounder fuse 0,75 A autoreset

- Bảo hành: 12 tháng. 

Giá: Vui lòng gọi